Non Contact Measurement Ultrasonic Sensor PVDF Low Power Consumption KUS600 Series

Non Contact Measurement Ultrasonic Sensor PVDF Low Power Consumption KUS600 Series

Fluid Ultrasonic Level Sensor

PVDF Non Contact Ultrasonic Sensor

0.6m Ultrasonic Level Transmitter

Place of Origin:

CHINA

পরিচিতিমুলক নাম:

KACISE

সাক্ষ্যদান:

CE

Model Number:

KUS600

আমাদের সাথে যোগাযোগ
একটি উদ্ধৃতি অনুরোধ করুন
পণ্যের বিবরণ
Range:
0.6m-5m, low-power product supports wide voltage input, this range is for 3.3V power supply (6m range customizable)
Unusable area:
0 ...0.6m
Power supply:
3.3V-24V
Power consumption:
less than 0.3mA when sleep, less than 20mA when emitting, less than 5mA than when measurement
Output signal:
0-5V /4-20mA/NPN/PNP/RS485
Electrical connection:
5-core cable (analog), 6-core cable (switch)
Ranging resolution:
1mm
Measurement accuracy:
0.5%-1 %F.S.
Temp. compensation:
Yes
Protection class:
IP66
বিশেষভাবে তুলে ধরা:

Fluid Ultrasonic Level Sensor

,

PVDF Non Contact Ultrasonic Sensor

,

0.6m Ultrasonic Level Transmitter

পেমেন্ট ও শিপিংয়ের শর্তাবলী
Minimum Order Quantity
1PCS
মূল্য
আলোচনাযোগ্য
Packaging Details
each unit has individual box and all boxes are packed in standard packages or customers requests available
Delivery Time
5-8 work days
Payment Terms
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability
1000 Piece/Pieces per Week negotiable
পণ্যের বর্ণনা

KUS600 Series Ultrasonic Sensor PVDF Non-contact measurement Low power consumption

 

Features
 
 Non-contact measurement
 PVDF casing for corrosion environment
 Low power consumption solution
 Various output options, wide voltage power supply
 
KUS600 low-power ultrasonic liquid level gauge is a real low-power ultrasonic sensor with low operating current, the stable time is short and the stability is good. We use nearly new ICs, usually with very low power consumption.The circuit in the sensor consists of three parts, the basic circuit of the transmitting circuit, the receiving circuit and the single-chip microcomputer. The single-chip microcomputer realizes power consumption management by enabling the work of various parts of the control circuit, and then controls power consumption.When the microcontroller itself is not working, it enters sleep mode to further reduce power consumption.
 
Dimension
 
Unit in the diagram is mm.
Non Contact Measurement Ultrasonic Sensor PVDF Low Power Consumption KUS600 Series 0
 
 
 
Parameter
 
Range

0.6m-5m, low-power product supports wide voltage input, this range is for 3.3V power supply (6m range customizable)

Unusable area 0 ...0.6m
Power supply 3.3V-24V
Power consumption less than 0.3mA when sleep, less than 20mA when emitting, less than 5mA than when measurement
Output signal 0-5V /4-20mA/NPN/PNP/RS485
Electrical connection 5-core cable (analog), 6-core cable (switch)
Ranging resolution 1mm
Measurement accuracy 0.5%-1 %F.S.
Temp. compensation Yes
Working temperature -25…70(233...358K)
Storage temperature -40…85(233...358K)
Protection class IP66
Casing Material PVDF

 

 

 

Description of Sensor Functions
 
Adjusting the analogue output.
The analogue output can be programed as the user want. Such as working at switch output or working at liner output all the parameters can be set by the RS485 interface. There are 8 types of output functions can be programed. All the setting routine as follows, step 1 set one pointed distance by the RS485, step 2 set another pointed distance by the RS485. Step3 set the output type liner or switch, and set the related output options Step4 reboot the sensor. 1. Window mode normally-open and liner mode positive slope output function. 2. Window mode normally-closed and liner mode negative slope output function. 3. Single switching point, normally-open function. 4. Single switching point, normally-closed function. 5. Single switch point with hysteresis gap normally-open function. 6. Single switch point with hysteresis gap normally-closed function. 7. Detection of object presence-normal open function. 8. Detection of object presence-closed open function. Switching point, Setting distance only after power on. The internal clock can assure can't be changed after 5 minutes after power on. If want to change the switching point, the user can only set the request distance after power restart.
 
For the RS485 output type.
There are 2 kinds of working style, One for auto measure, the sensor will measure the distance or level repeatedly, and the measurement period can be set by the UART. The measure result can be fetched every time. The other style is power save mode when the sensor is sleep, until the sensor received the inquiry command with pre-code. Communication protocol is Modus-RTU. For example the measure result can be read by access the register 0x101 by Modbus protocol. For more information please contact us for the software engineering guide.
 