KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen

KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen

Place of Origin:

CHINA

পরিচিতিমুলক নাম:

kacise

সাক্ষ্যদান:

CE

Model Number:

KFDO310

আমাদের সাথে যোগাযোগ
একটি উদ্ধৃতি অনুরোধ করুন
পণ্যের বিবরণ
Measuring principle:
fluorescence
Range:
0ー20 mg/L (0ー200% saturation, 25 °C)
Resolution:
0.01 mg/l, 0.1 °C
Precision:
± 2% f.s. , ± 0.5 °C
Temperature compensation:
Automatic temperature compensation (PT1000)
Output mode:
RS-485 bus, Modbus-RTU protocol
পেমেন্ট ও শিপিংয়ের শর্তাবলী
Minimum Order Quantity
0-100
মূল্য
$0-$2000
Packaging Details
Common package or custom package
Delivery Time
3-10days
Payment Terms
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability
100
পণ্যের বর্ণনা

1.Principle

KFDO310 integrated on-line fluorescence dissolved oxygen sensor is designed and made based on the quenching principle of excited fluorescence of specific substances in physics. The blue light from the light-emitting diode illuminates the fluorescent material on the inner surface of the fluorescent cap. The fluorescent material on the inner surface is excited and emits red light. By detecting the phase difference between the red light and the blue light, and comparing it with the internal calibration value, the concentration of oxygen molecule can be calculated, and the final value can be output by temperature automatic compensation.

2.Feature

  • No electrolytes, no polarization
  • No need to consume oxygen, not affected by the flow rate
  • Built-in temperature sensor, automatic temperature compensation
  • Free from chemicals like sulfides
  • Small drift, fast response, more accurate measurement
  • Maintenance-free, long service life, lower use cost
  • Fluorescent caps are easy to replace
  • RS-485 interface, Modbus-RTU protocol

3.Technical Specifications

Model number KFDO310
Measuring principle fluorescence
Range 0ー20 mg/L (0ー200% saturation, 25 °C)
Resolution 0.01 mg/l, 0.1 °C
Precision ± 2% f.s. , ± 0.5 °C
Temperature compensation Automatic temperature compensation (PT1000)
Output mode RS-485 bus, Modbus-RTU protocol
Working conditions 0ー45 °C, < 0.2 mpa
Storage temperature - 5 ~ 65 °C
Installation mode Immersion mounting
Cable length 5 meters, other length can be customized
Power consumption < 0.05 W
Power supply 12 ~ 24 VDC ± 10%
Protection level IP68
Calibration Two-point calibration
Fluorescent cap life Guaranteed Use for one year (under normal use)
Material for sensor housing Pom and 316L stainless steel
 
4.Dimensional Drawing

 

KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen 0

 

 

 

5.Installation and Electrical Connection

Installs

KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen 1

The temperature sensing part should be immersed below the liquid surface to avoid collision with the film head surface. The head part of the membrane should be free from sediment.

 

Tips:Galvanic Dissolved Oxygen Sensors

 

 

KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen 2

Cross-section of a galvanic dissolved oxygen sensor.

The final electrochemical dissolved oxygen sensor is galvanic. In a galvanic dissolved oxygen sensor, the electrodes are dissimilar metals. Metals have different electropotentials based on their activity series (how readily they give or accept electrons) 17. When placed in an electrolyte solution, the potential between dissimilar metals causes them to self-polarize 16. This self-polarization means that a galvanic DO sensor does not require any warm-up time. In order to reduce oxygen without an external applied potential, the difference in potential between the anode and the cathode should be at least 0.5 volts 16.

The anode in a galvanic dissolved oxygen sensor is usually zinc, lead, or another active metal while the cathode is silver or another noble metal 3. The electrolyte solution can be sodium hydroxide, sodium chloride, or another inert electrolyte 8,27. The electrochemical reaction in galvanic DO sensors is very similar to the reaction in polarographic DO sensors, but without the need for a separate, constant potential. The dissimilar electrodes self-polarize, with the electrons traveling internally from the anode to the cathode 7. The cathode remains inert, serving only to pass on electrons and it does not interfere in the reaction 20. Thus, the anode is oxidized and oxygen is reduced at the surface of the cathode. These reactions occur as follows:

 

KFDO310 Online Fluorescence Dissolved Oxygen Sensor no electrolytes no polarization no need to consume oxygen 3
Zn/Pb – zinc or lead anode
NaCl and H2O – sodium chloride solution
Ag – silver cathode *inert electrode, does not react*

Zinc Anode Reaction and Oxidation
2Zn —-> 2Zn2+ + 4e

Silver Cathode Reaction and Oxygen Reduction
*The Ag cathode is inert and only passes electron without participating in the reaction* 18
O2 + 4e + 2H2O —-> 4OH
4OH + 2Zn2+ —-> 2Zn (OH)2

Overall Reaction
O2 + 2H2O + 2Zn —-> 2 Zn (OH)2
As in the polarographic dissolved oxygen sensor reaction, the cathode is left out of the equation because it is an inert electrode 18. The silver cathode accepts electrons from the anode and passes them on to the oxygen molecules. This transaction occurs at the cathode’s surface 8. The current produced by the reduction of oxygen is proportional to the partial pressure of oxygen in the water sample 15.

The zinc hydroxide that is produced by these reactions is precipitated out into the electrolyte solution. This precipitate is visible as a white solid at the tip of the sensor 7. This precipitate neither coats the anode nor consumes the electrolyte, and thus does not affect the sensor’s performance until the quantity becomes excessive. If this happens, it may interfere with the ions’ ability to carry current between the cathode and the anode 22. When the sensor output is unusually low or the readings do not stabilize, it is necessary to replace the electrolyte solution 7.

As the electrodes in a galvanic DO sensor are self-polarizing, the oxidation of zinc will continue to occur even when the instrument is not in use. A galvanic dissolved oxygen sensor will operate efficiently even as the zinc anode is consumed, though it may need to be replaced more frequently than a polarographic DO sensor.

 

 